Metadata-Version: 2.1
Name: tc2100
Version: 0.1.2
Summary: Receive data from a compatible USB digital thermometer
Home-page: https://github.com/cbs228/tc2100
Author: Colin S.
Author-email: 3526918+cbs228@users.noreply.github.com
License: MIT
Description: # TC2100 Thermometer Interface
        
        > Receive measurements from your TC2100 or other compatible digital thermometer
        > over USB.
        
        ## Motivation
        
        The TC2100 is a digital thermometer which supports
        
        * two simultaneous measurement channels; and
        * seven standard types of thermocouples.
        
        Although it is usable as a standalone meter, it also includes a USB interface
        for real-time computer output.
        
        The manufacturer provides software for the USB interface. *This is not it.*
        This is unsupported, third-party software which was developed by reverse
        engineering.
        
        The `tc2100` module is a python 3.6 software development kit for receiving
        real-time temperature measurements. It includes a console script, `tc2100dump`,
        for logging measurements to [csv](https://docs.python.org/3.6/library/csv.html)
        files.
        
        ## Supported Devices
        
        At present, only one device is supported by this module.
        
        | Name                   | Vendor ID (hex)  | Product ID (hex)  |
        |------------------------|------------------|-------------------|
        | TC2100                 | `10c4`           | `ea60`            |
        
        Other devices have not been tested and are unlikely to work. If you have another
        device which works, open a bug report and ask that it be added to this table.
        
        ## The Fine Print
        
        In case you missed it above, this project is not affiliated with the original
        manufacturer(s). To our knowledge, the telemetry format is not specified in any
        [other] public documents. It has been reverse-engineered without assistance or
        support from the manufacturer. Read the
        [license](https://github.com/cbs228/tc2100/blob/master/LICENSE) carefully, as
        it may affect your rights. There is no warranty.
        
        *Use of these programs in safety-critical applications is strongly discouraged.*
        
        ## Installation
        
        ```bash
        pip3 install tc2100
        ```
        
        This module requires [twisted](http://twistedmatrix.com/) and
        [pyserial](https://pyserial.readthedocs.io/en/latest/pyserial.html). The pip
        package will automatically install these dependencies.
        
        ## Quick Start
        
        Using the supplied USB cable, connect a TC2100 thermometer to your computer.
        Hold down the "PC Link" button until the meter beeps and the "USB" indicator
        illuminates. Then run:
        
        ```bash
        tc2100dump --out temperatures.csv
        ```
        
        If you receive "`permission denied`" errors on Linux, you need to grant your
        user account permission to use serial devices. On most distributions, including
        Ubuntu and CentOS, this can be accomplished by adding yourself to the `dialout`
        group:
        
        ```bash
        sudo usermod -a -G dialout "$USER"
        ```
        
        Once you perform the above modification, you will need to log out and log back
        in again. Never run this program as root!
        
        When running `tc2100dump`, you may omit the `--out` argument to write
        measurements to standard output. You may also call this module as an executable
        with
        
        ```bash
        python3 -m tc2100 --out temperatures.csv
        ```
        
        The script will attempt to auto-detect the correct port for your thermometer.
        If auto-detection fails, you may specify the port manually:
        
        ```bash
        tc2100dump --port /dev/ttyUSB0 --out temperatures.csv
        ```
        
        ## Development Status
        
        This module is likely *feature-complete*. It does what I need it to do, and
        additional features are not planned. Bug reports which are broadly categorized
        as feature requests will probably be rejected. I am also unable to support the
        inclusion of additional devices—even similar ones.
        
        If you observe inconsistencies or other issues with the telemetry output, and
        can identify them, please submit a bug report. If able, please include a capture
        of the serial data stream and the expected behavior with your report.
        
        Pull requests within the scope of this project are welcome, especially if they
        fix bugs. Please ensure that your PRs include tests and pass the included `tox`
        checks.
        
        ## Technical Details
        
        The TC2100 incorporates a UART-to-USB chipset, which emulates a serial port over
        USB. When plugged in, most computers will automatically detect it as a serial
        port, like `/dev/ttyUSB0` or `COM1`. No additional drivers are required.
        
        The thermometer has a USB vendor ID of `0x10c4` and a product ID of `0xea60`.
        The meter's serial adapter uses `9600` baud with the common `8N1` format: eight
        data bits, no parity, and one stop bit.
        
        Once the "PC Link" button is pressed, updates begin to stream immediately, at
        regular intervals. Each update is an 18 byte packet which begins with the hex
        bytes `b"\x65\x14"` and ends with a CRLF (`b"\x0d\x0a"`). Multi-byte quantities
        are sent `big endian`.
        
        This is an example update, in hex:
        
        ```
        65 14 00 00 00 00 8D 09 0C 01 81 88 40 00 02 05 0D 0A
        ```
        
        Bytes are decoded as follows:
        
        | Offset (dec)  | C Type        | Description                     |
        |---------------|---------------|---------------------------------|
        | 0             | `uint8[2]`    | Header                          |
        | 2             | `uint8[3]`    | Unknown—always zeros            |
        | 5             | `int16`       | Channel 1 measurement           |
        | 7             | `int16`       | Channel 2 measurement           |
        | 9             | `uint8`       | Thermocouple type, other data   |
        | 10            | `uint8`       | Display unit, other data        |
        | 11            | `uint8`       | Channel 1 flags                 |
        | 12            | `uint8`       | Channel 2 flags                 |
        | 13            | `uint8`       | Hours                           |
        | 14            | `uint8`       | Minutes                         |
        | 15            | `uint8`       | Seconds                         |
        | 16            | `uint8[2]`    | CRLF                            |
        
        * The update message cannot be expressed as a C struct, as it lacks the proper
          alignment.
        * Measurement **values** are
          - expressed in tenths of degrees
          - in sign-magnitude format. The sign bit is part of the flag bytes (11 and 12)
          - expressed in the same units as the thermometer is set to display. Byte 10
            indicates the unit of measure.
        * Channel **flags** are OR'd together:
          - Valid measurement: `0x08`
          - Invalid measurement: `0x40`. Channels which do not have a thermocouple
            connected will have this flag.
          - Negative measurement: `0x80`
        * The thermocouple **type** and temperature **units** are stored in the least
          significant nibble of those bytes. The upper nibble contains other data.
        
        The above measurement is in degrees Celsius. The channel 1 measurement is
        `-14.1 °C`, and the channel 2 measurement is invalid.
        
        Further details are included in the python class `tc2100.Observation`. Unit
        tests include more sample data.
        
        ----
        
        License - [MIT](https://github.com/cbs228/tc2100/blob/master/LICENSE)
        
Keywords: thermometer tc2100 thermocouple 10c4:ea60 serial driver
Platform: any
Classifier: Development Status :: 4 - Beta
Classifier: Intended Audience :: Developers
Classifier: Intended Audience :: Science/Research
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Classifier: Environment :: Console
Classifier: Programming Language :: Python :: 3.7
Classifier: Programming Language :: Python :: 3.8
Classifier: Topic :: Software Development :: Libraries :: Python Modules
Classifier: Topic :: System :: Hardware :: Hardware Drivers
Classifier: Framework :: Twisted
Requires-Python: >=3.6
Description-Content-Type: text/markdown