==================================   BM   ======================================


BM calculate the spectum of Bending Magnets as a function of the photon energy.
It also calculates the angular distribution of the emission.



References:
	G K Green, "Spectra and optics of synchrotron radiation"
		BNL 50522 report (1976)
	A A Sokolov and I M Ternov, Synchrotron Radiation,
		Akademik-Verlag, Berlin, 1968



               Description of the input parameters for BM:
               ===========================================

TYPE OF CALCULATION: Select between spctrum or angle distribuion options.

B FROM:For selecting B field from either Magnetic radius of the bending
	magnet or magnetic field.
	(The three precedent parameters are related by:
	Radius [m] = (10/3) * Energy[GeV] / B[Tesla])

MACHINE RADIUS: The radius of the Bending Magnet in meters.

MAGNETIC FIELD: The magnetic field of the bending magnet in Tesla.

BEAM ENERGY:    The electron beam energy in GeV.

BEAM CURRENT:   The electron beam current in Ampers.

HORIZ DIV:      The horizontal divergence in mrad.

PSI (VERTICAL DIV) FOR ENERGY SPECTRA: For the calculation of the FLux and
		Power density spectra, different options of Psi can be selected:
	Full (integrated in Psi): Spectra are calculated integrated from all
		space over Psi
	At Psi=0: Spectra (pre mrad in Psi) at the center of the beam Psi=0
	In [Psi_Min,Psi_max]: Spectra integrated over a given interval in Psi.
		The values of the interval (Psi_Min and Psi_max) must be
		entered and also the mumber of points for integration in Psi.
	At Psi=Psi_Min: Single angle for spectrum calculations

MIN PHOTON ENERGY:  Minimum photon energy for the calculated spectrum, in eV.

MAX PHOTON ENERGY:  Maximum photon energy for the calculated spectrum, in eV.

NUMBER OF ENERGY POINTS: Number of energy points for the energy spectra

SEPARATION BETWEEN ENERGY POINTS: Two options are available for creating the
		energy array:
	Lin: Energy points are a linear array (constant step)
	Log: Energy points are a logarithmic array (step changes as log)

MAX Psi[mrad] FOR ANGULAR PLOTS: Define the maximum value of Psi in mrad to
		be used when selecting the angular distribution plots, i.e.:
	Plot angular distribution (all wavelengths)
	Plot angular distribution (one wavelength)

Psi min [mrad]: minimum value of Psi [mrad] for integration. Used in
	Plot energy spectra in [Psi_Min,Psi_Max] angular range
	Plot (angular,energy) distribution
    Use also this entry to place the Psi value to be used when calculating
	Plot energy spectra at Psi=Psi_Min

NUMBER OF PSI POINTS: Number of points for Psi integration or for the
	(angular,energy) mesh distribution. Please note that in the case that
	an integration over an angular interval [Psi_Min,Psi_Max] is chosen,
	the accuracy of the result may depends on this number of points in
	the integration grid.

DUMP FILE: Optionaly writes results in an output file: bm.spec